## Rook CephCluster and CephFS values for the rook-cephfs storage recipe.
## Chart: rook-ceph-cluster from https://charts.rook.io/release
##
## Ceph runs on the same nodes as the model servers: every node labelled
## llm-d.ai/ceph-storage=true hosts mons, MDS daemons, and OSDs on its local
## NVMe. The pool, daemon and client settings below are tuned for large,
## regenerable KV-cache blocks, not for durable general-purpose storage.

clusterName: rook-ceph

toolbox:
  enabled: true

# Pin the exact version: a floating major tag can pull a newer point release
# for some daemons and leave the operator stuck reconciling mixed versions.
cephImage:
  repository: quay.io/ceph/ceph
  tag: v19.2.4

cephClusterSpec:
  dataDirHostPath: /var/lib/rook

  mon:
    count: 3
    allowMultiplePerNode: false
  mgr:
    count: 2
    allowMultiplePerNode: false
    modules:
      - name: pg_autoscaler
        enabled: true
  dashboard:
    enabled: true

  # Host networking keeps the CephFS data path (kernel client -> OSD) off the
  # pod overlay. Set addressRanges to the subnets of your high-speed NICs so
  # that the OSDs advertise addresses on them; without it Ceph binds to each
  # node's primary (management) address. List every subnet the OSDs may use,
  # plus the management subnet the mons live on. Put site-specific values in
  # your own file and pass it with ROOK_CLUSTER_EXTRA_VALUES.
  #
  # Apply this at install time. Switching a running cluster from the pod
  # network to host networking breaks mon quorum.
  network:
    provider: host
    # addressRanges:
    #   public:
    #     - 10.243.65.0/24  # management subnet (mons)
    #     - 10.0.0.0/16     # data NIC 1
    #     - 10.1.0.0/16     # data NIC 2

  cephConfig:
    global:
      # The KV-cache filesystem's pools below keep a single copy.
      mon_allow_pool_size_one: "true"
      # 4 MiB messenger receive buffer.
      ms_tcp_rcvbuf: "4194304"
    osd:
      # 8 GiB memory target, below the 12 GiB container limit set in resources.
      osd_memory_target: "8589934592"
      # 16 shards x 4 workers per OSD. Sized for nodes with many cores; watch
      # OSD CPU saturation before reusing these on smaller nodes.
      osd_op_num_shards_ssd: "16"
      osd_op_num_threads_per_shard_ssd: "4"
      # Favor client reads and writes over recovery and scrub.
      osd_mclock_profile: high_client_ops
      ms_async_op_threads: "5"
      # Workaround for high OSD CPU with more discard threads on Ceph 19 (Squid).
      # Re-evaluate after a Ceph upgrade.
      bdev_async_discard_threads: "1"
    mds:
      # 4 GiB metadata cache, within the 8 GiB MDS container limit.
      mds_cache_memory_limit: "4294967296"
    client:
      # 32 MiB read-ahead, larger metadata and object caches, and more
      # operations in flight.
      client_readahead_max_bytes: "33554432"
      client_cache_size: "65536"
      client_oc_size: "1073741824"
      objecter_inflight_ops: "4096"
      objecter_inflight_op_bytes: "524288000"

  resources:
    osd:
      requests:
        cpu: "2"
        memory: "8Gi"
      limits:
        cpu: "4"
        memory: "12Gi"
    mon:
      requests:
        cpu: "500m"
        memory: "2Gi"
      limits:
        cpu: "2"
        memory: "4Gi"
    mgr:
      requests:
        cpu: "500m"
        memory: "1Gi"
      limits:
        cpu: "2"
        memory: "2Gi"

  placement:
    all:
      nodeAffinity:
        requiredDuringSchedulingIgnoredDuringExecution:
          nodeSelectorTerms:
            - matchExpressions:
                - key: llm-d.ai/ceph-storage
                  operator: In
                  values:
                    - "true"
      tolerations:
        - key: nvidia.com/gpu
          operator: Exists
          effect: NoSchedule

  storage:
    # useAllNodes is narrowed to the labelled nodes by the placement above.
    useAllNodes: true
    useAllDevices: false
    # WARNING: every unused device matching this regex becomes an OSD. The
    # default takes nvme1n1..nvme7n1 and leaves nvme0n1 alone. Check `lsblk`
    # on each node and adjust the filter so that it does not match the OS or
    # model-cache drives.
    deviceFilter: "^nvme[1-7]n1$"

cephBlockPools: []
cephObjectStores: []

cephFileSystems:
  - name: kvcache-fs
    spec:
      # One copy of the metadata as well: this filesystem holds nothing but
      # cache, so losing it means recreating it and refilling the cache. Raise
      # to 3 if the filesystem must survive the loss of an OSD.
      metadataPool:
        replicated:
          size: 1
          requireSafeReplicaSize: false
      dataPools:
        - name: data0
          deviceClass: nvme
          # KV cache is recomputable: losing an object costs one prefill, not
          # data. A single copy gives the full raw NVMe capacity to the cache.
          # Raise size to 2 or 3 if warm cache must survive a node failure.
          # Never store model weights or other durable data in this pool.
          replicated:
            size: 1
            requireSafeReplicaSize: false
          # With a single placement group all I/O lands on one primary OSD.
          parameters:
            pg_num: "128"
      preserveFilesystemOnDelete: false
      metadataServer:
        activeCount: 2
        activeStandby: true
        resources:
          requests:
            cpu: "2"
            memory: "4Gi"
          limits:
            cpu: "4"
            memory: "8Gi"
        priorityClassName: system-cluster-critical
        placement:
          nodeAffinity:
            requiredDuringSchedulingIgnoredDuringExecution:
              nodeSelectorTerms:
                - matchExpressions:
                    - key: llm-d.ai/ceph-storage
                      operator: In
                      values:
                        - "true"
          # Spread the MDS daemons over the storage nodes.
          podAntiAffinity:
            preferredDuringSchedulingIgnoredDuringExecution:
              - weight: 100
                podAffinityTerm:
                  topologyKey: kubernetes.io/hostname
                  labelSelector:
                    matchLabels:
                      app: rook-ceph-mds
          tolerations:
            - key: nvidia.com/gpu
              operator: Exists
              effect: NoSchedule
    storageClass:
      enabled: true
      isDefault: false
      name: rook-cephfs-fast
      pool: data0
      reclaimPolicy: Delete
      allowVolumeExpansion: true
      volumeBindingMode: "Immediate"
      # No access-time writes, and 64 MiB read/write sizes for the large
      # sequential KV block transfers. Mount options apply at mount time:
      # restart the model servers after changing them.
      mountOptions:
        - noatime
        - nodiratime
        - wsize=67108864
        - rsize=67108864
      parameters:
        csi.storage.k8s.io/provisioner-secret-name: rook-csi-cephfs-provisioner
        csi.storage.k8s.io/provisioner-secret-namespace: "{{ .Release.Namespace }}"
        csi.storage.k8s.io/controller-expand-secret-name: rook-csi-cephfs-provisioner
        csi.storage.k8s.io/controller-expand-secret-namespace: "{{ .Release.Namespace }}"
        csi.storage.k8s.io/controller-publish-secret-name: rook-csi-cephfs-provisioner
        csi.storage.k8s.io/controller-publish-secret-namespace: "{{ .Release.Namespace }}"
        csi.storage.k8s.io/node-stage-secret-name: rook-csi-cephfs-node
        csi.storage.k8s.io/node-stage-secret-namespace: "{{ .Release.Namespace }}"